HPE FlexNetwork 5130 24G 4SFP+ EI Switch HP RENEW JG932A
I/O ports and slots 24 RJ-45 autosensing 10/100/1000 ports (IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T); Duplex: 10BASE-T/100BASE-TX: half or full; 1000BASE-T: full only 4 SFP+ fixed 1000/10000 SFP+ ports Additional ports and slots 1 RJ-45 serial console port Physical characteristics Dimensions 17.32(w) x 6.3(d) x 1.72(h) in (44 x 16 x 4.36 cm) (1U height) Weight 11.02 lb (5 kg) Memory and processor 1 GB SDRAM, 128 MB flash; packet buffer size:... Celý popis
Popis
I/O ports and slots
24 RJ-45 autosensing 10/100/1000 ports (IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T); Duplex: 10BASE-T/100BASE-TX: half or full; 1000BASE-T: full only 4 SFP+ fixed 1000/10000 SFP+ ports
Additional ports and slots
1 RJ-45 serial console port
Physical characteristics
Dimensions 17.32(w) x 6.3(d) x 1.72(h) in (44 x 16 x 4.36 cm) (1U height) Weight 11.02 lb (5 kg)
Memory and processor
1 GB SDRAM, 128 MB flash; packet buffer size: 1.5 MB
Mounting and enclosure
Mounts in an EIA standard 19-inch telco rack or equipment cabinet (hardware included)
Performance
1000 Mb Latency< 5 µs 10 Gbps Latency< 1.5 µs Throughput 96 Mpps Routing/Switching capacity 128 Gbps Routing table size 512 entries (IPv4), 256 entries (IPv6) MAC address table size 16384 entries
Reliability
MTBF (years) 98.1
Environment
Operating temperature 32°F to 113°F (0°C to 45°C) Operating relative humidity 10% to 90%, noncondensing Nonoperating/Storage temperature -40°F to 158°F (-40°C to 70°C) Nonoperating/Storage relative humidity 5% to 95%, noncondensing Acoustic High-speed fan: 39.7 dB; ISO 7779
Electrical characteristics
Frequency 50/60 Hz Maximum heat dissipation 64/88 BTU/hr (67.52/92.84 kJ/hr) AC voltage 100-240 VAC Current 2 A Maximum power rating 26 W Idle power 19 W
Notes
Idle power is the actual power consumption of the device with no ports connected. Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated.
Safety
UL 60950-1; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser Products-Part 2; IEC 60950-1; CAN/CSA-C22.2 No. 60950-1; Anatel; ULAR; GOST; EN 60950-1/A11; FDA 21 CFR Subchapter J; NOM; ROHS Compliance
Emissions
EMC Directive 2004/108/EC; FCC (CFR 47, Part 15) Class A; EN 61000-4-11:2004; ANSI C63.4-2009; EN 61000-3-3:2008; VCCI V-4/2012.04; EN 6100-3-2:2006+A1:2009 + A2:2009; EN 61000-3-2:2006+A1:2009+A2:2009 ; EN 61000-4-3:2006; EN 61000-4-4:2012; EN 61000-4-5:2006; EN 61000-4-6:2009; AS/NZS CISPR 22:2009 Class A; CISPR 22:2008 Class A; EN 55022:2010 Class A; EN 61000-4-29: 2000; CISPR 24:2010; EN 300 386 V1.6.1; VCCI V-3/2013.04 Class A
Immunity
Generic EN 55024 ESD EN300 386
Management
IMC - Intelligent Management Center; command-line interface; Web browser; SNMP Manager
Services
Refer to the HP website at: www.hp.com/networking/services for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office.
HPE FlexNetwork 5130 24G 4SFP+ EI Switch (JG932A)
I/O ports and slots
24 RJ-45 autosensing 10/100/1000 ports (IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T); Duplex: 10BASE-T/100BASE-TX: half or full; 1000BASE-T: full only
4 SFP+ fixed 1000/10000 SFP+ ports
Additional ports and slots
1 RJ-45 serial console port
Physical characteristics
Dimensions
17.32(w) x 6.3(d) x 1.72(h) in (44 x 16 x 4.36 cm) (1U height)
Weight
11.02 lb (5 kg)
Memory and processor
1 GB SDRAM, 512 MB flash; packet buffer size: 1.5 MB
Mounting and enclosure
Mounts in an EIA standard 19-inch telco rack or equipment cabinet (hardware included)
Performance
IPv6 Ready Certified
1000 Mb Latency
< 5 µs
10 Gbps Latency
< 3 µs
Throughput
96 Mpps
Routing/Switching capacity
128 Gbps
Routing table size
512 entries (IPv4), 256 entries (IPv6)
MAC address table size
16384 entries
Environment
Operating temperature
23°F to 113°F (-5°C to 45°C)
Operating relative humidity
10% to 90%, noncondensing
Non-operating/Storage temperature
-40°F to 158°F (-40°C to 70°C)
Non-operating/Storage relative humidity
5% to 95%, noncondensing
Acoustic
High-speed fan: 39.7 dB; ISO 7779
Electrical characteristics
Frequency
50/60 Hz
Maximum heat dissipation
64/88 BTU/hr (67.52/92.84 kJ/hr)
Voltage
100 - 240 VAC, rated
Current
2 A
Maximum power rating
26 W
Idle power
19 W
Notes
- Idle power is the actual power consumption of the device with no ports connected.
- Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated.
Safety
UL 60950-1; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser Products-Part 2; IEC 60950-1; CAN/CSA-C22.2 No. 60950-1; Anatel; ULAR; GOST; EN 60950-1/A11; FDA 21 CFR Subchapter J; NOM; ROHS Compliance
Emissions
EMC Directive 2004/108/EC; FCC (CFR 47, Part 15) Class A; EN 61000-4-11:2004; ANSI C63.4-2009; EN
61000-3-3:2008; VCCI V-4/2012.04; EN 6100-3-2:2006+A1:2009 + A2:2009; EN 61000-3-2:2006+A1:2009+A2:2009 ; EN 61000-4-3:2006; EN 61000-4-4:2012; EN 61000-4-5:2006; EN 61000-4-6:2009; AS/NZS CISPR 22:2009 Class A; CISPR 22:2008 Class A; EN 55022:2010 Class A; EN 61000-4-29: 2000; CISPR 24:2010; EN 300 386 V1.6.1; VCCI V-3/2013.04 Class A
Immunity
Generic
EN 55024
ESD
EN300 386
Management
IMC - Intelligent Management Center; command-line interface; Web browser; SNMP Manager
Services
Refer to the Hewlett Packard Enterprise website at http://www.hpe.com/networking/services for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local Hewlett Packard Enterprise sales office.
24 RJ-45 autosensing 10/100/1000 ports (IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T); Duplex: 10BASE-T/100BASE-TX: half or full; 1000BASE-T: full only 4 SFP+ fixed 1000/10000 SFP+ ports
Additional ports and slots
1 RJ-45 serial console port
Physical characteristics
Dimensions 17.32(w) x 6.3(d) x 1.72(h) in (44 x 16 x 4.36 cm) (1U height) Weight 11.02 lb (5 kg)
Memory and processor
1 GB SDRAM, 128 MB flash; packet buffer size: 1.5 MB
Mounting and enclosure
Mounts in an EIA standard 19-inch telco rack or equipment cabinet (hardware included)
Performance
1000 Mb Latency< 5 µs 10 Gbps Latency< 1.5 µs Throughput 96 Mpps Routing/Switching capacity 128 Gbps Routing table size 512 entries (IPv4), 256 entries (IPv6) MAC address table size 16384 entries
Reliability
MTBF (years) 98.1
Environment
Operating temperature 32°F to 113°F (0°C to 45°C) Operating relative humidity 10% to 90%, noncondensing Nonoperating/Storage temperature -40°F to 158°F (-40°C to 70°C) Nonoperating/Storage relative humidity 5% to 95%, noncondensing Acoustic High-speed fan: 39.7 dB; ISO 7779
Electrical characteristics
Frequency 50/60 Hz Maximum heat dissipation 64/88 BTU/hr (67.52/92.84 kJ/hr) AC voltage 100-240 VAC Current 2 A Maximum power rating 26 W Idle power 19 W
Notes
Idle power is the actual power consumption of the device with no ports connected. Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated.
Safety
UL 60950-1; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser Products-Part 2; IEC 60950-1; CAN/CSA-C22.2 No. 60950-1; Anatel; ULAR; GOST; EN 60950-1/A11; FDA 21 CFR Subchapter J; NOM; ROHS Compliance
Emissions
EMC Directive 2004/108/EC; FCC (CFR 47, Part 15) Class A; EN 61000-4-11:2004; ANSI C63.4-2009; EN 61000-3-3:2008; VCCI V-4/2012.04; EN 6100-3-2:2006+A1:2009 + A2:2009; EN 61000-3-2:2006+A1:2009+A2:2009 ; EN 61000-4-3:2006; EN 61000-4-4:2012; EN 61000-4-5:2006; EN 61000-4-6:2009; AS/NZS CISPR 22:2009 Class A; CISPR 22:2008 Class A; EN 55022:2010 Class A; EN 61000-4-29: 2000; CISPR 24:2010; EN 300 386 V1.6.1; VCCI V-3/2013.04 Class A
Immunity
Generic EN 55024 ESD EN300 386
Management
IMC - Intelligent Management Center; command-line interface; Web browser; SNMP Manager
Services
Refer to the HP website at: www.hp.com/networking/services for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office.
HPE FlexNetwork 5130 24G 4SFP+ EI Switch (JG932A)
I/O ports and slots
24 RJ-45 autosensing 10/100/1000 ports (IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T); Duplex: 10BASE-T/100BASE-TX: half or full; 1000BASE-T: full only
4 SFP+ fixed 1000/10000 SFP+ ports
Additional ports and slots
1 RJ-45 serial console port
Physical characteristics
Dimensions
17.32(w) x 6.3(d) x 1.72(h) in (44 x 16 x 4.36 cm) (1U height)
Weight
11.02 lb (5 kg)
Memory and processor
1 GB SDRAM, 512 MB flash; packet buffer size: 1.5 MB
Mounting and enclosure
Mounts in an EIA standard 19-inch telco rack or equipment cabinet (hardware included)
Performance
IPv6 Ready Certified
1000 Mb Latency
< 5 µs
10 Gbps Latency
< 3 µs
Throughput
96 Mpps
Routing/Switching capacity
128 Gbps
Routing table size
512 entries (IPv4), 256 entries (IPv6)
MAC address table size
16384 entries
Environment
Operating temperature
23°F to 113°F (-5°C to 45°C)
Operating relative humidity
10% to 90%, noncondensing
Non-operating/Storage temperature
-40°F to 158°F (-40°C to 70°C)
Non-operating/Storage relative humidity
5% to 95%, noncondensing
Acoustic
High-speed fan: 39.7 dB; ISO 7779
Electrical characteristics
Frequency
50/60 Hz
Maximum heat dissipation
64/88 BTU/hr (67.52/92.84 kJ/hr)
Voltage
100 - 240 VAC, rated
Current
2 A
Maximum power rating
26 W
Idle power
19 W
Notes
- Idle power is the actual power consumption of the device with no ports connected.
- Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated.
Safety
UL 60950-1; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser Products-Part 2; IEC 60950-1; CAN/CSA-C22.2 No. 60950-1; Anatel; ULAR; GOST; EN 60950-1/A11; FDA 21 CFR Subchapter J; NOM; ROHS Compliance
Emissions
EMC Directive 2004/108/EC; FCC (CFR 47, Part 15) Class A; EN 61000-4-11:2004; ANSI C63.4-2009; EN
61000-3-3:2008; VCCI V-4/2012.04; EN 6100-3-2:2006+A1:2009 + A2:2009; EN 61000-3-2:2006+A1:2009+A2:2009 ; EN 61000-4-3:2006; EN 61000-4-4:2012; EN 61000-4-5:2006; EN 61000-4-6:2009; AS/NZS CISPR 22:2009 Class A; CISPR 22:2008 Class A; EN 55022:2010 Class A; EN 61000-4-29: 2000; CISPR 24:2010; EN 300 386 V1.6.1; VCCI V-3/2013.04 Class A
Immunity
Generic
EN 55024
ESD
EN300 386
Management
IMC - Intelligent Management Center; command-line interface; Web browser; SNMP Manager